科技报告详细信息
Generalization of the FRAM's Bias
Vo, Duc T.
United States. Department of Energy. Office of Scientific and Technical Information.
关键词: Efficiency;    Uranium;    Gamma Spectroscopy;    38 Radiation Chemistry, Radiochemistry, And Nuclear Chemistry;    F Codes;   
DOI  :  10.2172/861271
RP-ID  :  LA-14253
RP-ID  :  W-7405-ENG-36
RP-ID  :  861271
美国|英语
来源: UNT Digital Library
PDF
【 摘 要 】

The Fixed-Energy Response-Function Analysis with Multiple Efficiency (FRAM) code was developed at Los Alamos National Laboratory to measure the gamma-ray spectrometry of the isotopic composition of plutonium, uranium, and other actinides. Its reported uncertainties of the results come from the propagation of the statistics in the peak areas only. No systematic error components are included in the reported uncertainties. We have done several studies and found that the FRAM's statistical precision can be reasonably represented by its reported uncertainties. The FRAM's biases or systematic uncertainties can come from a variety of sources and can be difficult to determine. We carefully examined the FRAM analytical results of the archival plutonium data and of the data specifically acquired for this isotopic uncertainty analysis project and found the relationship between the bias and other parameters. We worked out the equations representing the biases of the measured isotopes from each measurement using the internal parameters in the spectrum such as peak resolution and shape, region of analysis, and burnup (for plutonium) or enrichment (for uranium).

【 预 览 】
附件列表
Files Size Format View
861271.pdf 1493KB PDF download
  文献评价指标  
  下载次数:12次 浏览次数:8次