PRECLOSURE CONSEQUENCE ANALYSES FOR LICENSE APPLICATION
Tsai, S.
United States. Department of Energy. Yucca Mountain Project Office.
关键词: Particle Resuspension;    Dusts;    Positioning;    License Applications;    Neutrons;   
DOI  :  10.2172/841290
RP-ID  :  000-00C-MGR0-00900-000-00B
RP-ID  :  NA
RP-ID  :  841290
美国|英语
来源: UNT Digital Library
PDF
【 摘 要 】
Radiological consequence analyses are performed for potential releases from normal operations in surface and subsurface facilities and from Category 1 and Category 2 event sequences during the preclosure period. Surface releases from normal repository operations are primarily from radionuclides released from opening a transportation cask during dry transfer operations of spent nuclear fuel (SNF) in Dry Transfer Facility 1 (DTF 1), Dry Transfer Facility 2 (DTF 2), the Canister Handling facility (CHF), or the Fuel Handling Facility (FHF). Subsurface releases from normal repository operations are from resuspension of waste package surface contamination and neutron activation of ventilated air and silica dust from host rock in the emplacement drifts. The purpose of this calculation is to demonstrate that the preclosure performance objectives, specified in 10 CFR 63.111(a) and 10 CFR 63.111(b), have been met for the proposed design and operations in the geologic repository operations area. Preclosure performance objectives are discussed in Section 6.2.3 and are summarized in Tables 1 and 2.
【 预 览 】
附件列表
Files Size Format View
841290.pdf 18021KB PDF download