FINAL REPORT - HYBRID-MIXING TESTS SUPPORTING THE CONCENTRATE RECEIPT VESSEL (CRV-VSL-00002A/2B) CONFIGURATION | |
GUERRERO, HECTORN. | |
Savannah River Site (S.C.) | |
关键词: Particulates; Testing; Slurries; Pulse Jet Mixers; Simulation; | |
DOI : 10.2172/835549 RP-ID : WSRC-TR-2004-00398SRNL-RPP-2004-00060 RP-ID : AC09-96SR18500 RP-ID : 835549 |
|
美国|英语 | |
来源: UNT Digital Library | |
【 摘 要 】
The Savannah River National Laboratory (SRNL) has performed scaled physical modeling of Pulse Jet Mixing Systems applicable to the Concentrate Receipt Vessel (CRV) of Hanford's Waste Treatment Plant (WTP) as part of the overall effort to validate pulse jet mixer (PJM) mixing in WTP vessels containing non-Newtonian fluids. The strategy developed by the Pulse Jet Mixing Task Team was to construct a quarter-scale model of the CRV, use a clear simulant to understand PJM mixing behavior, and down-select from a number of PJM configurations to a ''best design'' configuration. This ''best design'' would undergo final validation testing using a particulate simulant that has rheological properties closely similar to WTP waste streams. The scaled PJM mixing tests were to provide information on the operating parameters critical for the uniform movement (total mobilization) of these non-Newtonian slurries. Overall, 107 tests were performed during Phase I and Phase II testing.
【 预 览 】
Files | Size | Format | View |
---|---|---|---|
835549.pdf | 1523KB | download |