科技报告详细信息
EVALUATION OF MIXING IN THE SLURRY MIX EVAPORATOR AND MELTER FEED TANK
MARINIK, ANDREW
Savannah River Site (S.C.)
关键词: Evaporators;    Sludges;    Plastics;    Mixing,Vortex;    Mixtures;   
DOI  :  10.2172/835228
RP-ID  :  WSRC-TR-2004-00436
RP-ID  :  AC09-96SR18500
RP-ID  :  835228
美国|英语
来源: UNT Digital Library
PDF
【 摘 要 】

The Defense Waste Processing Facility (DWPF) vitrifies High Level radioactive Waste (HLW) currently stored in underground tanks at the Savannah River Site (SRS). The HLW currently being processed is a waste sludge composed primarily of metal hydroxides and oxides in caustic slurry. These slurries are typically characterized as Bingham Plastic fluids. The HLW undergoes a pretreatment process in the Chemical Process Cell (CPC) at DWPF. The processed HLW sludge is then transferred to the Sludge Receipt and Adjustment Tank (SRAT) where it is acidified with nitric and formic acid then evaporated to concentrate the solids. Reflux boiling is used to strip mercury from the waste and then the waste is transferred to the Slurry Mix Evaporator tank (SME). Glass formers are added as a frit slurry to the SME to prepare the waste for vitrification. This mixture is evaporated in the SME to the final concentration target. The frit slurry mixture is then transferred to the Melter Feed Tank (MFT) to be fed to the melter.