科技报告详细信息
Measurement of Thermal Diffusity and Flow Resistance for TCAP Materials
Steimke, John
Savannah River Site (S.C.)
关键词: Tcap;    Thermal Conductivity;    08 Hydrogen;    Absorption;    Thermal Diffusivity;   
DOI  :  10.2172/835064
RP-ID  :  WSRC-TR-2004-00479
RP-ID  :  AC09-96SR18500
RP-ID  :  835064
美国|英语
来源: UNT Digital Library
PDF
【 摘 要 】

SRS uses the Thermal Cycling Absorption Process (TCAP) to separate isotopes of hydrogen. The frequency of thermal cycles is a limit of the productivity of the process and that frequency is largely determined by the thermal diffusivity of the absorbent material. For a given tube diameter, a larger thermal diffusivity decreases the time required for each cycle. In 1998, the Engineering Development Laboratory measured thermal diffusivity and thermal conductivity for three TCAP materials in helium.

【 预 览 】
附件列表
Files Size Format View
835064.pdf 274KB PDF download
  文献评价指标  