科技报告详细信息
Evaluation of Proposed New LLW Disposal Activity Disposal of LLW in an Engineered Trench rather than in Slit Trenches
WILHITE, ELMERL.
Savannah River Site (S.C.)
关键词: Dimensions;    Capacity;    Performance Assessment;    Evaluation;    12 Management Of Radioactive Wastes, And Non-Radioactive Wastes From Nuclear Facilities;   
DOI  :  10.2172/834282
RP-ID  :  WSRC-RP-2000-00217, Rev 1
RP-ID  :  AC09-96SR18500
RP-ID  :  834282
美国|英语
来源: UNT Digital Library
PDF
【 摘 要 】

Following issuance of the original document (i.e., rev. 0), it was discovered that an error was made in stating the dimensions and volume of the Engineered Trench and the incorrect volume was used in calculating the concentration limits (i.e. the inventory limit divided by the volumetric waste capacity of the unit) in the tables. The terminology of calling the average concentrations ''limits'' proved problematic in managing the inventory limits through the deviation process. Since the average concentration values presented serve no essential purpose (Waste Acceptance Criteria are derived from the inventory limits), they were removed from the tables. Also, the name of the disposal unit was changed from the MegaTrench to the Engineered Trench. For clarification, a statement was added that differences in dimensions of disposal units of less than about 10 percent are inconsequential from a PA perspective.

【 预 览 】
附件列表
Files Size Format View
834282.pdf 74KB PDF download
  文献评价指标  
  下载次数:12次 浏览次数:60次