The objective of this program was to develop and test a system that would detect and image buried plastic and ceramic pipe. The system is designed to detect variations in the electric permeability of soil corresponding to the presence of a buried plastic pipe. The Gas Technology Institute (GTI) proposed to develop a compact and inexpensive capacitive tomography-imaging sensor that can be placed on the ground to image objects embedded in the soil. The system provides a coarse image, which allows the operator to identify a buried object's location both horizontally and vertically.
【 预 览 】
Files | Size | Format | View |
---|---|---|---|
823716.pdf | 1775KB | download |