Ion exchanger resin fluid film mass transfer coefficients and the ionic diffusivities from which they are derived are often measured by use of ion exchange resin columns. Such tests, usually run dynamically using short resin beds, are often performed using relatively high (ppm) concentrations of ions to accurately measure output concentrations as a function of flow rate. The testing described herein was performed to determine fluid film ionic diffusivities for cationic concentrations typical of ultrapure water ({le}ppb levels) containing ppm levels of ammonia. Effective ionic diffusivities at these low ionic concentrations and high pHs were needed to complete a computer model (SIMIX) to be used in ion exchange simulations. SIMIX is a generalized multicomponent ion exchange model designed to simulate the removal of divalent cations from ultrapure water.