FIELD SCREENING FOR HALOGENATED VOLATILE ORGANIC COMPOUNDS
Schabron, John F. ; Joseph F. Rovani, Jr. ; Bomstad, Theresa M.
Western Research Institute (United States)
关键词: Air Conditioners;    Freezers;    Toluene;    Leak Detectors;    Refrigerants;   
DOI  :  10.2172/820761
RP-ID  :  NONE
RP-ID  :  FC26-98FT40322
RP-ID  :  820761
美国|英语
来源: UNT Digital Library
PDF
【 摘 要 】

Western Research Institute (WRI) is continuing work toward the development of new screening methodology and a test kit to measure halogenated volatile organic compounds (VOCs) in the field. Heated diode and corona discharge sensors are commonly used to detect leaks of refrigerants from air conditioners, freezers, and refrigerators. They are both selective to the presence of halogens. In prior work, the devices were tested for response to carbon tetrachloride, heptane, toluene, and water vapors. In the current work, sensor response was evaluated with sixteen halogenated VOCs relative to carbon tetrachloride. The results show that the response of the various chlorinated VOCs is within an order of magnitude of the response to carbon tetrachloride for each of the sensors. Thus, for field screening a single response factor can be used. Both types of leak detectors are being further modified to provide an on-board LCD signal readout, which is related to VOC concentration. The units will be fully portable and will operate with 115-V line or battery power. Signal background, noise level, and response data on the Bacharach heated diode detector and the TIF corona discharge detector show that when the response curves are plotted against the log of concentration, the plot is linear to the upper limit for the particular unit, with some curvature at lower levels. When response is plotted directly against concentration, the response is linear at the low end and is curved at the high end. The dynamic ranges for carbon tetrachloride of the two devices from the lower detection limit (S/N=2) to signal saturation are 4-850 vapor parts per million (vppm) for the corona discharge unit and 0.01-70 vppm for the heated diode unit. Additional circuit modifications are being made to lower the detection limit and increase the dynamic response range of the corona discharge unit. The results indicate that both devices show potential utility for future analytical method development work toward the goal of developing a portable test kit for screening halogenated VOCs in the field.

【 预 览 】
附件列表
Files Size Format View
820761.pdf 962KB PDF download
  文献评价指标  
  下载次数:7次 浏览次数:14次