| Heat Balance Study for Submersible Mixer Pump | |
| Lee, S.Y. | |
| Savannah River Site (S.C.) | |
| 关键词: Heat Transfer; Waste Retrieval; Radioactive Wastes; Mathematical Models; Storage Facilities; | |
| DOI : 10.2172/816695 RP-ID : WSRC-TR-2002-00585 RP-ID : AC09-96SR18500 RP-ID : 816695 |
|
| 美国|英语 | |
| 来源: UNT Digital Library | |
PDF
|
|
【 摘 要 】
A transient heat balance model was developed to assess the impact of a Submersible Mixer Pump (SMP) on waste temperature during the process of waste mixing and removal for the Type-I SRS tanks. The model results will be mainly used to determine the SMP design impacts on the waste tank temperature during operations and to develop a specification for a new SMP design to replace existing long-shaft mixer pumps used during waste removal. The model will also be used to provide input to the operation planning. This planning will be used as input to pump run duration in order to maintain temperature requirements within the tank during SMP operation.
【 预 览 】
| Files | Size | Format | View |
|---|---|---|---|
| 816695.pdf | 903KB |
PDF