科技报告详细信息
MOX Average Power Test 30 GWd/MT PIE: Quick Look
MORRIS, RN
Oak Ridge National Laboratory
关键词: Post-Irradiation Examination;    Fuel Pins;    Irradiation;    Fission;    11 Nuclear Fuel Cycle And Fuel Materials;   
DOI  :  10.2172/814226
RP-ID  :  ORNL/MD/LTR-208
RP-ID  :  AC05-00OR22725
RP-ID  :  814226
美国|英语
来源: UNT Digital Library
PDF
【 摘 要 】

This report summarizes the early results of the post irradiation examination of the 30 GWd/MT MOX Average Power Test Capsules (numbers 3 and 10). The purpose of this preliminary examination is to document and monitor the progress of the MOX Average Power Test Irradiation. The capsules and their fuel pins were found to be in excellent condition. Measurement of the fission gas release fraction (about 1.50 to 2.26%), preliminary fuel stack gamma scan measurements, and preliminary fuel pin diameter measurements indicate that the fuel is behaving as expected.

【 预 览 】
附件列表
Files Size Format View
814226.pdf 1406KB PDF download
  文献评价指标  
  下载次数:16次 浏览次数:22次