科技报告详细信息
Plutonium Finishing Plant (PFP) Waste Composition and High Efficiency Particulate Air Filter Loading | |
ZIMMERMAN, B.D. | |
CH2M Hill Hanford Group, Inc. | |
关键词: Air Filters; Particulates; Air; Wastes; Efficiency; | |
DOI : 10.2172/805655 RP-ID : RPP-7396, Rev.0 RP-ID : AC27-99RL14047 RP-ID : 805655 |
|
美国|英语 | |
来源: UNT Digital Library | |
【 摘 要 】
This analysis evaluates the effect of the Plutonium Finishing Plant (PFP) waste isotopic composition on Tank Farms Final Safety Analysis Report (FSAR) accidents involving high-efficiency particulate air (HEPA) filter failure in Double-Contained Receiver Tanks (DCRTs). The HEPA Filter Failure--Exposure to High Temperature or Pressure, and Steam Intrusion From Interfacing Systems accidents are considered. The analysis concludes that dose consequences based on the PFP waste isotopic composition are bounded by previous FSAR analyses. This supports USQD TF-00-0768.
【 预 览 】
Files | Size | Format | View |
---|---|---|---|
805655.pdf | 2172KB | download |