Engineering Task Plan for the Integrity Assessment Examination of Double Contained Receiver Tanks (DCRT) Catch Tanks and Ancillary facilities
BECKER, D.L.
Numatec Hanford Co.
关键词: Radioactive Waste Facilities;    Radioactive Waste Processing;    Tanks;    12 Management Of Radioactive Wastes, And Non-Radioactive Wastes From Nuclear Facilities;    Evaluation;   
DOI  :  10.2172/804221
RP-ID  :  RPP-5963, Rev.0
RP-ID  :  AC06-96RL13200
RP-ID  :  804221
美国|英语
来源: UNT Digital Library
PDF
【 摘 要 】

This Engineering Task Plan (ETP) presents the integrity assessment examination of three DCRTs, seven catch tanks, and two ancillary facilities located in the 200 East and West Areas of the Hanford Site. The integrity assessment examinations, as described in this ETP, will provide the necessary information to enable the independently qualified registered professional engineer (IQRPE) to assess the condition and integrity of these facilities. The plan is consistent with the Double-Shell Tank Waste Transfer Facilities Integrity Assessment Plan.

【 预 览 】
附件列表
Files Size Format View
804221.pdf 3555KB PDF download