| DENSE MEDIA CYCLONE OPTIMIZATION | |
| Luttrell, Gerald H. | |
| National Energy Technology Laboratory (U.S.) | |
| 关键词: 01 Coal, Lignite, And Peat; Segregation; Coal; Optimization; Particle Size; | |
| DOI : 10.2172/804101 RP-ID : FC26-01NT41061--05 RP-ID : FC26-01NT41061 RP-ID : 804101 |
|
| 美国|英语 | |
| 来源: UNT Digital Library | |
PDF
|
|
【 摘 要 】
The test data obtained from the Baseline Assessment that compares the performance of the density traces to that of different sizes of coal particles is now complete. The experimental results show that the tracer data can indeed be used to accurately predict HMC performance. The following conclusions were drawn: (i) the tracer curve is slightly sharper than curve for coarsest size fraction of coal (probably due to the greater resolution of the tracer technique), (ii) the Ep increases with decreasing coal particle size, and (iii) the Ep values are not excessively large for the well-maintained HMC circuits. The major problems discovered were associated with improper apex-to-vortex finder ratios and particle hang-up due to media segregation. Only one plant yielded test data that were typical of a fully optimized level of performance.
【 预 览 】
| Files | Size | Format | View |
|---|---|---|---|
| 804101.pdf | 166KB |
PDF