科技报告详细信息
| Justification for Shielded Receiver Tube Additional Lead Shielding | |
| Boger, R. M. | |
| CH2M Hill Hanford Group, Inc. | |
| 关键词: Shielding; Radioactive Wastes; Sampling; Tanks; 12 Management Of Radioactive Wastes, And Non-Radioactive Wastes From Nuclear Facilities; | |
| DOI : 10.2172/803011 RP-ID : RPP-6018, Rev.0 RP-ID : AC27-99RL14047 RP-ID : 803011 |
|
| 美国|英语 | |
| 来源: UNT Digital Library | |
PDF
|
|
【 摘 要 】
In order to reduce high radiation dose rates encountered when core sampling some radioactive waste tanks the addition of 240 lbs. of lead shielding is being considered to the shielded receiver tube on core sample trucks No.1, No.3 and No.4. The lead shielding is 4 inch diameter x 1/2 inch thick half rounds that have been installed around the SR tube over its' full length. Using three unreleased but independently reviewed structural analyses HNF-6018 justifies the addition of the lead shielding.
【 预 览 】
| Files | Size | Format | View |
|---|---|---|---|
| 803011.pdf | 3399KB |
PDF