Methodology for Predicting Flammable Gas Mixtures in Double Contained Receiver Tanks [SEC 1 THRU SEC 3] | |
HEDENGREN, D.C. | |
Lockheed Martin Hanford Corporation | |
关键词: 08 Hydrogen; Pumping; Gases; Methane; Ammonia; | |
DOI : 10.2172/801131 RP-ID : RPP-4941, Rev.0 RP-ID : AC27-99RL14047 RP-ID : 801131 |
|
美国|英语 | |
来源: UNT Digital Library | |
【 摘 要 】
This methodology document provides an estimate of the maximum concentrations of flammable gases (ammonia, hydrogen, and methane) which could exist in the vapor space of a double-contained receiver tank (DCRT) from the simultaneous saltwell pumping of one or more single-shell tanks (SSTs). This document expands Calculation Note 118 (Hedengren et a1 1997) and removes some of the conservatism from it, especially in vapor phase ammonia predictions. The methodologies of Calculation Note 118 (Hedengren et a1 1997) are essentially identical for predicting flammable gas mixtures in DCRTs from saltwell pumping for low DCRT ventilation rates, 1e, < 1 cfm. The hydrogen generation model has also been updated in the methodology of this document.
【 预 览 】
Files | Size | Format | View |
---|---|---|---|
801131.pdf | 19218KB | download |