| BSW Well Evaluation Report | |
| Noonkester, J.V. | |
| Savannah River Site (S.C.) | |
| 关键词: Monitoring; Ground Water; Samplers; Water Wells; 11 Nuclear Fuel Cycle And Fuel Materials; | |
| DOI : 10.2172/801020 RP-ID : WSRC-TR-2002-00289 RP-ID : AC09-96SR18500 RP-ID : 801020 |
|
| 美国|英语 | |
| 来源: UNT Digital Library | |
PDF
|
|
【 摘 要 】
The BSW series wells are located in the Mixed Waste Management Facility and are part of the groundwater monitoring program at Savannah River Site. These wells have had persistent problems that prevent successful sampling that dates back to their installation. Only thirty-two of the fifty-three BSW wells were successfully sampled during 4th quarter, 2001. These problems were previously investigated by looking at field sampling logbooks from 4th quarter 2001 and other background information to try to identify causes for the high rate of sampling failure. Several possible causes were identified and reported in memorandum, SRT-EST-2002-00059. The memorandum recommended that an evaluation be performed on each well to identify problems and their causes and to correct them when possible. Environmental Restoration Division followed up on this recommendation and requested Savannah River Technology Center to perform an evaluation. This report includes the results of the evaluation performed on the BSW wells.
【 预 览 】
| Files | Size | Format | View |
|---|---|---|---|
| 801020.pdf | 916KB |
PDF