U-235 Holdup Measurements in the 321-M Lathe HEPA Banks | |
Salaymeh, S.R. | |
Savannah River Site (S.C.) | |
关键词: Criticality; Particulates; Nondestructive Analysis; Material Unaccounted For; Air Filters; | |
DOI : 10.2172/799413 RP-ID : WSRC-TR-2001-00536 RP-ID : AC09-96SR18500 RP-ID : 799413 |
|
美国|英语 | |
来源: UNT Digital Library | |
【 摘 要 】
The Analytical Development Section of Savannah River Technology Center (SRTC) was requested by the Facilities Decommissioning Division (FDD) to determine the holdup of enriched uranium in the 321-M facility as part of an overall deactivation project of the facility. The results of the holdup assays are essential for determining compliance with the Waste Acceptance Criteria, Material Control and Accountability, and to meet criticality safety controls. This report covers holdup measurements of uranium residue in six high efficiency particulate air (HEPA) filter banks of the A-lathe and B-lathe exhaust systems of the 321-M facility. This report discusses the non-destructive assay measurements, assumptions, calculations, and results of the uranium holdup in these six items.
【 预 览 】
Files | Size | Format | View |
---|---|---|---|
799413.pdf | 147KB | download |