科技报告详细信息
A Peer Review of the Strategy for Characterizing Ransuranics and Technetium Contamination in Uranium Hexafluoride Tails Cylinders
Sengupta, S.K. ; Randich, E. ; Avci, H.I. ; Steindler, M.J. ; Brumburgh, G.P.
Lawrence Livermore National Laboratory
关键词: Uranium Hexafluoride;    Portsmouth Gaseous Diffusion Plant;    Polychlorinated Biphenyls;    Gaseous Diffusion Plants;    Depleted Uranium;   
DOI  :  10.2172/793929
RP-ID  :  UCRL-ID-140343
RP-ID  :  W-7405-Eng-48
RP-ID  :  793929
美国|英语
来源: UNT Digital Library
PDF
【 摘 要 】

This document provides the findings from a peer review of the Oak Ridge National Laboratory (ORNL) Hightower 2000 study, which set forth a strategy for characterization of low levels of radioactive contaminants in depleted uranium hexafluoride (DUF{sub 6}) cylinders at the Oak Ridge, Paducah, and Portsmouth gaseous diffusion plants. The information from that study will be used in a DOE-issued request for proposal (RFP) for conversion services from the private sector, to assist vendors in reducing costs associated with contingencies relating to handling this DUF{sub 6} with elevated transuranics (TRUs) and technetium (Tc). The Hightower study developed a general strategy for DUF{sub 6} sampling and analysis in accordance with their task but also recommended the following courses of action: (a) Collect and analyze liquid samples from the two identified Paducah Gaseous Diffusion Plant (PGDP) feed cylinders, feed the DUF{sub 6} into the cascades, and conduct an analysis on the resulting heels by washing and analyzing the wash rinsate; (b) Characterize the cylinder coatings to determine the extent and levels of polychlorinated biphenyl (PCB) contamination; and (c) Verify the characterization of the cylinder inventory's compliance with Department of Transportation (DOT) regulations and the American Society of Mechanical Engineers (ASME) pressure vessel code In addition to the above recommendations, the study also concluded that additional characterization is not likely to result in lower bids by prospective vendors, and that direct sampling of many older tails cylinders may be impractical.

【 预 览 】
附件列表
Files Size Format View
793929.pdf 520KB PDF download
  文献评价指标  
  下载次数:24次 浏览次数:11次