科技报告详细信息
| Scintillator Evaluation for High-Energy X-Ray Diagnostics | |
| Lutz, S. S. ; Baker, S. A. | |
| Bechtel Nevada Corporation | |
| 关键词: 46 Instrumentation Related To Nuclear Science And Technology; X-Ray Radiography; Quantum Efficiency; Lutetium Compounds; Resolution; | |
| DOI : 10.2172/790063 RP-ID : DOE/NV/11718--653 RP-ID : AC08-96NV11718 RP-ID : 790063 |
|
| 美国|英语 | |
| 来源: UNT Digital Library | |
PDF
|
|
【 摘 要 】
This report presents results derived from a digital radiography study performed using x-rays from a 2.3 MeV, rod-pinch diode. Detailed is a parameter study of cerium-doped lutetium ortho-silicate (LSO) scintillator thickness, as it relates to system resolution and detection quantum efficiency (DQE). Additionally, the detection statistics of LSO were compared with that of CsI(Tl). As a result of this study we found the LSO scintillator with a thickness of 3 mm to yield the highest system DQE over the range of spatial frequencies from 0.75 to 2.5 mm{sup -1}.
【 预 览 】
| Files | Size | Format | View |
|---|---|---|---|
| 790063.pdf | 501KB |
PDF