科技报告详细信息
Observation of the spread of the readings in the Linac toroids and BPMs
McCrory, Elliott S
Fermi National Accelerator Laboratory
关键词: Beam Position;    43 Particle Accelerators;    Beam Monitors;    Linear Accelerators;    Accuracy;   
DOI  :  10.2172/788461
RP-ID  :  FERMILAB-TM-2161
RP-ID  :  AC02-76CH03000
RP-ID  :  788461
美国|英语
来源: UNT Digital Library
PDF
【 摘 要 】

The readback accuracy on the high-energy toroids is about 0.26 mA. This does not consider, completely, the relative offsets among the toroids, just the accuracy of one reading on one toroid. Similarly, if you remove the way in which the beam moves in the beam pipe and ignore the relative offsets of the BPMs themselves, then the absolute accuracy of the reading on a BPM is 35 microns.

【 预 览 】
附件列表
Files Size Format View
788461.pdf 63KB PDF download
  文献评价指标  