科技报告详细信息
Waste Tank Size Determination for the Hanford River Protection Project Cold Test, Training, and Mockup Facility
Onishi, Yasuo ; Wells, Beric E ; Kuhn, William L
Pacific Northwest National Laboratory (U.S.)
关键词: Training;    Radioactive Waste Facilities;    Mockup;    Radioactive Waste Processing;    Performance Testing;   
DOI  :  10.2172/786783
RP-ID  :  PNNL-13448
RP-ID  :  AC06-76RLO1830
RP-ID  :  786783
美国|英语
来源: UNT Digital Library
PDF
【 摘 要 】

The objective of the study was to determine the minimum tank size for the Cold Test Facility process testing of Hanford tank waste. This facility would support retrieval of waste in 75-ft-diameter DSTs with mixer pumps and SSTs with fluidic mixers. The cold test model will use full-scale mixer pumps, transfer pumps, and equipment with simulated waste. The study evaluated the acceptability of data for a range of tank diameters and depths and included identifying how the test data would be extrapolated to predict results for a full-size tank.

【 预 览 】
附件列表
Files Size Format View
786783.pdf 1246KB PDF download
  文献评价指标  
  下载次数:26次 浏览次数:10次