科技报告详细信息
Nineteen-Foot Diameter Explosively Driven Blast Simulator
VIGIL,MANUEL G.
Sandia National Laboratories
关键词: Tunnels;    Explosions;    42 Engineering;    Simulators;    Design;   
DOI  :  10.2172/786632
RP-ID  :  SAND2001-2164
RP-ID  :  AC04-94AL85000
RP-ID  :  786632
美国|英语
来源: UNT Digital Library
PDF
【 摘 要 】

This report describes the 19-foot diameter blast tunnel at Sandia National Laboratories. The blast tunnel configuration consists of a 6 foot diameter by 200 foot long shock tube, a 6 foot diameter to 19 foot diameter conical expansion section that is 40 feet long, and a 19 foot diameter test section that is 65 feet long. Therefore, the total blast tunnel length is 305 feet. The development of this 19-foot diameter blast tunnel is presented. The small scale research test results using 4 inch by 8 inch diameter and 2 foot by 6 foot diameter shock tube facilities are included. Analytically predicted parameters are compared to experimentally measured blast tunnel parameters in this report. The blast tunnel parameters include distance, time, static, overpressure, stagnation pressure, dynamic pressure, reflected pressure, shock Mach number, flow Mach number, shock velocity, flow velocity, impulse, flow duration, etc. Shadowgraphs of the shock wave are included for the three different size blast tunnels.

【 预 览 】
附件列表
Files Size Format View
786632.pdf 11848KB PDF download
  文献评价指标  
  下载次数:6次 浏览次数:12次