【 摘 要 】

Ion exchange tests have been completed at the Savannah River Technology Center for British Nuclear Fuels Limited, Inc. as part of the Hanford River Protection Project. Radioactive cesium and technetium (pertechnetate form only) were removed by ion exchange from a sample of Envelope C salt solution from Hanford Tank 241-AN-102 (sample volume: approximately 18 L at 4.8 M Na plus). The original sample was diluted and subjected to strontium/transuranics (Sr/TRU) precipitation and filtration processes before ion exchange processing was performed. Batch contact and column tests for the ion exchange removal of cesium and technetium were then completed on the Sr/TRU-decontaminated product. Previous ion exchange tests were conducted on a smaller portion (0.5 L) of the Tank 241-AN-102 supernate sample, which had been similarly pretreated, and the results were reported in a separate document.