科技报告详细信息
Influence of Water Addition on Crystalline Silicotitanate Column Operation
Stallings, M.E.
Savannah River Site (S.C.)
关键词: Ion Exchange Materials;    Removal;    Flowsheets;    Radioactive Waste Processing;    Sampling;   
DOI  :  10.2172/786595
RP-ID  :  WSRC-TR-2001-00264
RP-ID  :  AC09-96SR18500
RP-ID  :  786595
美国|英语
来源: UNT Digital Library
PDF
【 摘 要 】

The proposed use of crystalline silicotitanate (CST) for removal of radiocesium from Savannah River high level waste has received significant research over the past few years. Engineering evaluations of the proposed flow sheet identified several risks. These risks include chemical and thermal stability of the resin, gas generation in the large ion exchange columns, and size reduction and sampling issues for interfacing with the Defense Waste Processing Facility. Research into these potential risks provided information that mitigates or eliminates these risks.

【 预 览 】
附件列表
Files Size Format View
786595.pdf 83KB PDF download
  文献评价指标  
  下载次数:15次 浏览次数:22次