科技报告详细信息
Beam tube vacuum in a Very Large Hadron Collider; Stage 1 VLHC
Pivi, M. ; Turner, W.C.
Lawrence Berkeley National Laboratory
关键词: Pumping;    Getters;    Linear Colliders;    43 Particle Accelerators;    Methane;   
DOI  :  10.2172/785292
RP-ID  :  LBNL--47810
RP-ID  :  AC03-76SF00098
RP-ID  :  785292
美国|英语
来源: UNT Digital Library
PDF
【 摘 要 】

Synchrotron radiation induced photodesorption in particle accelerators may lead to pressure rise and to beam-gas scattering losses, finally affecting the beam lifetime. We discuss the beam tube vacuum in the low field Stage 1 Very Large Hadron Collider VLHC. Since VLHC Stage 1 has a room temperature beam tube, a non-evaporable getter (NEG St101 strip) pumping system located inside a pumping antechamber, supplemented by lumped ion pumps for pumping methane is considered. A possible beam conditioning scenario is presented for reaching design intensity. The most important results are summarized in this paper. More detailed reports of the calculations will be presented at the PAC2001 Conference, Chicago, IL to be held in June 2001, and at the Snowmass Conference, CO, to be held on July 2001.

【 预 览 】
附件列表
Files Size Format View
785292.pdf 105KB PDF download
  文献评价指标  