DWPF Sampling Device Development Test Results and Design Recommendation
Wilds, G.W.
Savannah River Site (S.C.)
关键词: Flow Rate;    Radioactive Waste Facilities;    Samplers;    Sampling;    Process Solutions;   
DOI  :  10.2172/783931
RP-ID  :  DPST-84-850
RP-ID  :  AC09-76SR00001
RP-ID  :  783931
美国|英语
来源: UNT Digital Library
PDF
【 摘 要 】

This report summarizes the development and testing of a sample device for the DWPF sample cells. The clamp actuated manual Hydraguard valve used in conjunction with the concentric needle fill device is recommended for use in the DWPF. This is based on test results which indicate that this sampler is capable of obtaining samples within five percent of the solids concentration of the process stream at flow rates from 0.5 to 3.5 gpm.