科技报告详细信息
Lagrangian and Control Volume Models for Prediction of Cooling Lake Performance at SRP | |
Garrett, A.J. | |
Savannah River Site (S.C.) | |
关键词: Forecasting; Lagrangian Function; Mathematical Models; Cooling Ponds; 22 General Studies Of Nuclear Reactors; | |
DOI : 10.2172/782824 RP-ID : DPST-84-496 Rev. 1 RP-ID : AC09-76SR00001 RP-ID : 782824 |
|
美国|英语 | |
来源: UNT Digital Library | |
![]() |
【 摘 要 】
The model validation described in this document indicates that the methods described here and by Cooper (1984) for predicting the performance of the proposed L-Area cooling lake are reliable. Extensive observations from the Par Pond system show that lake surface temperatures exceeding 32.2 degrees C (90 degrees F) are attained occasionally in the summer in areas where there is little or no heating from the P-Area Reactor. Regulations which restrict lake surface temperatures to less than 32.2 degrees C should be structured to allow for these naturally-occurring thermal excursions.
【 预 览 】
Files | Size | Format | View |
---|---|---|---|
782824.pdf | 1459KB | ![]() |