Double alpha MEBT for H{sup {minus}} beam
Popovic, M.
Fermi National Accelerator Laboratory
关键词: Dimensions;    43 Particle Accelerators;    Quadrupoles;    Simulation;    Beam Transport;   
DOI  :  10.2172/772803
RP-ID  :  FERMILAB-TM-2138
RP-ID  :  AC02-76CH03000
RP-ID  :  772803
美国|英语
来源: UNT Digital Library
PDF
【 摘 要 】

This note describes simulation studies of the H{sup {minus}} beam matching condition between a 750keV rod radio-frequency quadrupole (RFQ) and the existing Fermilab drift tube linac (DTL). The RFQ design used in this study is that of an existing RFQ designed and built by A. Schempp from IAP-Goethe University. It is assumed that the medium-energy beam transport (MEBT) line uses hardware built for a positron emission tomography (PET) project. The MEBT is made out of two Alpha magnets and seven quadrupoles and was designed by D. Larson. The beam from the exit of the RFQ is matched to the entrance in the DTL in all three dimensions. The study shows that up to 65mA of H{sup {minus}} beam can be transported and cleanly injected into the present linac.