科技报告详细信息
Demonstration of advanced combustion NO{sub X} control techniques for a wall-fired boiler. Project performance summary, Clean Coal Technology Demonstration Program
Southern Company Services, Inc., Birmingham, AL (United States)
关键词: Boilers;    Pollution Control;    Power Generation;    Heat Rate;    Us Epa;   
DOI  :  10.2172/770998
RP-ID  :  DOE/FE-0429
RP-ID  :  770998
美国|英语
来源: UNT Digital Library
PDF
【 摘 要 】

The project represents a landmark assessment of the potential of low-NO{sub x} burners, advanced overtire air, and neural-network control systems to reduce NO{sub x} emissions within the bounds of acceptable dry-bottom, wall-fired boiler performance. Such boilers were targeted under the Clean Air Act Amendments of 1990 (CAAA). Testing provided valuable input to the Environmental Protection Agency ruling issued in March 1994, which set NO{sub x} emission limits for ''Group 1'' wall-fired boilers at 0.5 lb/10{sup 6} Btu to be met by January 1996. The resultant comprehensive database served to assist utilities in effectively implementing CAAA compliance. The project is part of the U.S. Department of Energy's Clean Coal Technology Demonstration Program established to address energy and environmental concerns related to coal use. Five nationally competed solicitations sought cost-shared partnerships with industry to accelerate commercialization of the most advanced coal-based power generation and pollution control technologies. The Program, valued at over $5 billion, has leveraged federal funding twofold through the resultant partnerships encompassing utilities, technology developers, state governments, and research organizations. This project was one of 16 selected in May 1988 from 55 proposals submitted in response to the Program's second solicitation. Southern Company Services, Inc. (SCS) conducted a comprehensive evaluation of the effects of Foster Wheeler Energy Corporation's (FWEC) advanced overfire air (AOFA), low-NO{sub x} burners (LNB), and LNB/AOFA on wall-fired boiler NO{sub x} emissions and other combustion parameters. SCS also evaluated the effectiveness of an advanced on-line optimization system, the Generic NO{sub x} Control Intelligent System (GNOCIS). Over a six-year period, SCS carried out testing at Georgia Power Company's 500-MWe Plant Hammond Unit 4 in Coosa, Georgia. Tests proceeded in a logical sequence using rigorous statistical analyses to establish the incremental performance impacts of each technology evaluated. Tests showed NO{sub x} reductions for AOFA, LNB, and LNB/AOFA of 24, 48, and 68 percent, respectively. GNOCIS demonstrated an additional 10-15 percent NO{sub x} reduction capability while improving boiler heat rate as well. This project was extended in 1999 to apply GNOCIS to other pieces of plant equipment, which may increase its commercial potential. Those results will be released under separate documentation. This report is issued now because of the extent of valuable information obtained to date.

【 预 览 】
附件列表
Files Size Format View
770998.pdf 1344KB PDF download
  文献评价指标  
  下载次数:16次 浏览次数:13次