科技报告详细信息
Thermal Decomposition of Radiation-Damaged Polystyrene
Klinger, J Abrefah GS
Pacific Northwest National Laboratory (U.S.)
关键词: Radioactive Waste Storage;    Uranium Oxides;    36 Materials Science;    Radioactive Waste Processing;    Polystyrene;   
DOI  :  10.2172/763386
RP-ID  :  PNNL-13313
RP-ID  :  AC06-76RL01830
RP-ID  :  763386
美国|英语
来源: UNT Digital Library
PDF
【 摘 要 】
The radiation-damaged polystyrene material (''polycube'') used in this study was synthesized by mixing a high-density polystyrene (''Dylene Fines No. 100'') with plutonium and uranium oxides. The polycubes were used on the Hanford Site in the 1960s for criticality studies to determine the hydrogen-to-fissile atom ratios for neutron moderation during processing of spent nuclear fuel. Upon completion of the studies, two methods were developed to reclaim the transuranic (TRU) oxides from the polymer matrix: (1) burning the polycubes in air at 873 K; and (2) heating the polycubes in the absence of oxygen and scrubbing the released monomer and other volatile organics using carbon tetrachloride. Neither of these methods was satisfactory in separating the TRU oxides from the polystyrene. Consequently, the remaining polycubes were sent to the Hanford Plutonium Finishing Plant (PFP) for storage. Over time, the high dose of alpha and gamma radiation has resulted in a polystyrene matrix that is highly cross-linked and hydrogen deficient and a stabilization process is being developed in support of Defense Nuclear Facility Safety Board Recommendation 94-1. Baseline processes involve thermal treatment to pyrolyze the polycubes in a furnace to decompose the polystyrene and separate out the TRU oxides. Thermal decomposition products from this degraded polystyrene matrix were characterized by Pacific Northwest National Laboratory to provide information for determining the environmental impact of the process and for optimizing the process parameters. A gas chromatography/mass spectrometry (GC/MS) system coupled to a horizontal tube furnace was used for the characterization studies. The decomposition studies were performed both in air and helium atmospheres at 773 K, the planned processing temperature. The volatile and semi-volatile organic products identified for the radiation-damaged polystyrene were different from those observed for virgin polystyrene. The differences were in the n umber of organic species generated and their concentrations.
【 预 览 】
附件列表
Files Size Format View
763386.pdf 1377KB PDF download
  文献评价指标  
  下载次数:4次 浏览次数:8次