科技报告详细信息
Calculation of the Aluminosilicate Half-Life Formation Time in the 2H Evaporator
Fondeur, F.F.
Savannah River Site (S.C.)
关键词: Evaporators;    Heat Transfer;    Radioactive Waste Facilities;    Aluminium Silicates;    Dissolution;   
DOI  :  10.2172/763271
RP-ID  :  WSRC-TR-2000-00267
RP-ID  :  DE-AC09-96SR18500
RP-ID  :  763271
美国|英语
来源: UNT Digital Library
PDF
【 摘 要 】

The 2H Evaporator contains large quantities of aluminosilicate solids deposited on internal fixtures. The proposed cleaning operations will dissolve the solids in nitric acid. Operations will then neutralize the waste prior to transfer to a waste tank. Combining recent calculations of heat transfer for the 2H Evaporator cleaning operations and laboratory experiments for dissolution of solid samples from the pot, the authors estimated the re-formation rate for aluminosilicates during cooling. The results indicate a half-life formation of 17 hours when evaporator solution cools from 60 degrees C and 9 hours when cooled from 90 degrees C.

【 预 览 】
附件列表
Files Size Format View
763271.pdf 695KB PDF download
  文献评价指标  
  下载次数:11次 浏览次数:24次