Status of Far Infrared Tangential Interferometry/Polarimetry (FIReTIP) on NSTX | |
Park, H.K. ; Edwards, S. ; Guttadora, L. ; Deng, B. ; Domier, C.W. ; Lee, K.C. ; Johnson, M. ; N.C. Luhmann, Jr. | |
Princeton University. Plasma Physics Laboratory. | |
关键词: Paramagnetism; Nstx Device; 70 Plasma Physics And Fusion Technology; Diamagnetism; Design; | |
DOI : 10.2172/761105 RP-ID : PPPL-3485 RP-ID : AC02-76CH03073 RP-ID : 761105 |
|
美国|英语 | |
来源: UNT Digital Library | |
【 摘 要 】
The Influence of paramagnetism and diamagnetism will significantly alter the vacuum toroidal magnetic field in the spherical torus. Therefore, plasma parameters dependent upon BT such as the q-profile and the local b value need an independent measurement of BT(r,t). The multi-chord Tangential Far Infrared Interferometer/Polarimeter (FIReTIP) system [1] currently under development for the National Spherical Torus Experiment (NSTX) will provide temporally and radially resolved toroidal field profile [BT(r,t)] and 2-D electron density profile [ne(r,t)] data. A two-channel interferometer will be operational this year and the full system will be ready by 2002.
【 预 览 】
Files | Size | Format | View |
---|---|---|---|
761105.pdf | 710KB | download |