Small Column Ion Exchange Testing of Superlig 644 for Removal of 137Cs from Hanford Tank Waste Envelope A (Tank 241-AW-101)
Kurath, DE ; Blanchard, DL ; Bontha, JR
Pacific Northwest National Laboratory (U.S.)
关键词: Ion Exchange Materials;    Removal;    12 Management Of Radioactive Wastes, And Non-Radioactive Wastes From Nuclear Facilities;    Hanford Reservation;    Radioactive Waste Processing;   
DOI  :  10.2172/758160
RP-ID  :  PNWD-3001
RP-ID  :  AC06-76RL01830
RP-ID  :  758160
美国|英语
来源: UNT Digital Library
PDF
【 摘 要 】

The current BNFL Inc. flow sheet for the pretreatment of the Hanford High-Level tank wastes includes the use of Superlig{reg_sign} materials for the removal of {sup 137}Cs from the aqueous fraction of the waste. The Superlig materials applicable to cesium removal include the cesium selective Superlig 632 and Superlig 644. These materials have been developed and supplied by IBC Advanced Technologies, Inc., American Fork, UT. The work contained in this report involves testing the Superlig 644 ion exchange material in a small dual column system (15 mL each; L/D = 5.7). The sample processed was approximately 2.5 L of diluted waste [Na{sup +}] = 4.6M from Tank 241-AW-101 (Envelope A). This waste had been previously clarified in a single tube cross-flow filtration unit. All ion exchange process steps were tested including resin bed preparation, loading, feed displacement water rinse, elution and resin regeneration. During the initial run, the lag column did not perform as expected so that the {sup 137}Cs concentration in the effluent composite was above the LAW treatment limits. This required a second column run with the partially decontaminated feed that was conducted at a higher flow rate. A summary of performance measures for both runs is shown in Table S1. The Cs {lambda} values represent a measure of the effective capacity of the SL-644 resin. The Cs {lambda} of 143 for the lead column in run 1 is very similar to the value obtained by the Savannah River Technology Center during Phase 1A testing. The larger Cs {lambda} value for run 2 reflects a general trend for the effective capacity of the SL-644 material to increase as the cesium concentration decreases. The low value for the lag column during the first run indicates that it did not perform as expected. This may have been due to insufficient conditioning of the bed prior to the start of the loading step or to air in the bed that caused channeling. Equilibrium data obtained with batch contacts using the AW-101 Cs IX feed indicates a range for the Cs {lambda} of 80--97. The maximum decontamination factor (DF) for {sup 137}CS is based on analysis of the first samples collected from each column and the concentration in the feed for each run. While the DF's are lower for the second run, this is attributed to the lower {sup 137}Cs concentration in the feed and the increased flowrate. The overall composite DF for run 2 was quite good since both columns functioned well. The overall DF for both runs was 3,000, which provided an effluent with a {sup 137}Cs concentration of 5.89E-02 Ci/m{sup 3} (C/C{sub 0} = 3.3 IE-04). The {sup 137}Cs concentration in the effluent composite was 7.3% of the contract limit for {sup 137}Cs and also below the basis of design limit.

【 预 览 】
附件列表
Files Size Format View
758160.pdf 6874KB PDF download
  文献评价指标  
  下载次数:15次 浏览次数:23次