Comparison of Dow Corning 544 antifoam to IIT747 antifoam in the 1/240 SRAT | |
Koopman, D.C. | |
Savannah River Site (S.C.) | |
关键词: Sludges; Radioactive Waste Facilities; Radioactive Waste Processing; Performance Testing; Mercury; | |
DOI : 10.2172/755212 RP-ID : WSRC-TR-99-00377 RP-ID : AC09-96SR18500 RP-ID : 755212 |
|
美国|英语 | |
来源: UNT Digital Library | |
【 摘 要 】
The Defense Waste Processing Facility requested that the Immobilization Technology Section compare the relative foaming tendencies of sludge simulant during simulated Chemical Processing Cell operations (HLW-DWPF-TTR-99-0012). Dow Corning 544 antifoam, currently used in DWPF, was compared to a new antifoam formulation developed at the Illinois Institute of Technology. A task plan was written and approved. The task plan deliverables included a recommendation on the choice of antifoam, an evaluation of the influence of solids concentration on foaming, an evaluation on the effect of boil-up rate on foaming, an estimate of the mass of steam stripped to remove 90 percent of the mercury, and a determination of the fate of mercury. Additional parameters to be investigated during experimentation included the maximum foam height observed, hydrogen generation rates, and nitrite destruction rates.
【 预 览 】
Files | Size | Format | View |
---|---|---|---|
755212.pdf | 489KB | download |