科技报告详细信息
Comparison of Dow Corning 544 antifoam to IIT747 antifoam in the 1/240 SRAT
Koopman, D.C.
Savannah River Site (S.C.)
关键词: Sludges;    Radioactive Waste Facilities;    Radioactive Waste Processing;    Performance Testing;    Mercury;   
DOI  :  10.2172/755212
RP-ID  :  WSRC-TR-99-00377
RP-ID  :  AC09-96SR18500
RP-ID  :  755212
美国|英语
来源: UNT Digital Library
PDF
【 摘 要 】

The Defense Waste Processing Facility requested that the Immobilization Technology Section compare the relative foaming tendencies of sludge simulant during simulated Chemical Processing Cell operations (HLW-DWPF-TTR-99-0012). Dow Corning 544 antifoam, currently used in DWPF, was compared to a new antifoam formulation developed at the Illinois Institute of Technology. A task plan was written and approved. The task plan deliverables included a recommendation on the choice of antifoam, an evaluation of the influence of solids concentration on foaming, an evaluation on the effect of boil-up rate on foaming, an estimate of the mass of steam stripped to remove 90 percent of the mercury, and a determination of the fate of mercury. Additional parameters to be investigated during experimentation included the maximum foam height observed, hydrogen generation rates, and nitrite destruction rates.

【 预 览 】
附件列表
Files Size Format View
755212.pdf 489KB PDF download
  文献评价指标  
  下载次数:45次 浏览次数:29次