科技报告详细信息
Coordinate Standard Measurement Development
Hanshaw, R.A.
Kansas City Plant (U.S.)
关键词: Modifications;    Coordinates;    Sampling;    Reliability;    Computer Codes;   
DOI  :  10.2172/751342
RP-ID  :  KCP-613-6286
RP-ID  :  AC04-76DP00613
RP-ID  :  751342
美国|英语
来源: UNT Digital Library
PDF
【 摘 要 】

A Shelton Precision Interferometer Base, which is used for calibration of coordinate standards, was improved through hardware replacement, software geometry error correction, and reduction of vibration effects. Substantial increases in resolution and reliability, as well as reduction in sampling time, were achieved through hardware replacement; vibration effects were reduced substantially through modification of the machine component dampening and software routines; and the majority of the machine's geometry error was corrected through software geometry error correction. Because of these modifications, the uncertainty of coordinate standards calibrated on this device has been reduced dramatically.

【 预 览 】
附件列表
Files Size Format View
751342.pdf 542KB PDF download