科技报告详细信息
Ultrasonic Examination of Double-Shell Tank 214-AW-102 Knuckle Region. Examination completed February 2003
Pardini, Allan F. ; Posakony, Gerald J.
Pacific Northwest National Laboratory (U.S.)
关键词: Ronde;    Walls 241-Aw-102;    Double-Shell Tank;    Ultrasoanic;    241-Aw-102;   
DOI  :  10.2172/15010205
RP-ID  :  PNNL-14265 Rev. 0
RP-ID  :  AC05-76RL01830
RP-ID  :  15010205
美国|英语
来源: UNT Digital Library
PDF
【 摘 要 】

COGEMA Engineering Corporation (COGEMA), under a contract from CH2M Hill Hanford Group (CH2M Hill), has performed an ultrasonic examination of the knuckle region of Double-Shell Tank 241-AW-102 utilizing the Remotely Operated Nondestructive Examination (RONDE) system. The purpose of this examination was to provide information that could be used to evaluate the integrity of the knuckle region of the primary tank. The requirements for the ultrasonic examination of Tank 241-AW-102 were to detect, characterize (identify, size, and locate), and record measurements made of any circumferentially oriented cracks that might be present in the knuckle area of the primary tank. Any measurements that exceed the requirements set forth in the Engineering Task Plan (ETP), RPP-7869, are reported to CH2M Hill and the Pacific Northwest National Laboratory (PNNL) for further evaluation. Under the contract with CH2M Hill, all data is to be recorded on disk and paper copies of all measurements are provided t o PNNL for third-party evaluation. PNNL is responsible for preparing a report(s) that describes the results of the COGEMA ultrasonic examinations.

【 预 览 】
附件列表
Files Size Format View
15010205.pdf 318KB PDF download
  文献评价指标  
  下载次数:18次 浏览次数:20次