科技报告详细信息
Results of Performance Evaluation Testing of Electrical Leak-Detection Methods at the Hanford Mock Tank Site--FY 2002-2003
Barnett, D. Brent ; Gee, Glendon W. ; Sweeney, Mark D. ; Johnson, Michael D. ; Medina, Victor F. ; Mendoza, Donaldo P. ; Fritz, Brad G. ; Khan, Fenton ; Daily, William D. ; Fink, James B. ; Levitt, Marc T. ; Binley, Andrew M.
Pacific Northwest National Laboratory (U.S.)
关键词: Leak Detectors;    Radioactive Waste Storage;    Storage Facilities;    Leak Testing;    Performance;   
DOI  :  10.2172/15010193
RP-ID  :  PNNL-14192
RP-ID  :  AC05-76RL01830
RP-ID  :  15010193
美国|英语
来源: UNT Digital Library
PDF
【 摘 要 】

Application of two electrical resistivity methods at the Hanford Site Mock Tank during 2002, indicate the viability of the methods as possible leak-detection tools for SST retrieval operations. Electrical Resistivity Tomography and High-Resolution Resistivity were used over a 109-day period to detect leakage of a waste simulant beneath the tank. The results of the test indicate that both of these two methods, and subset methods may be applicable to SST leak detection.

【 预 览 】
附件列表
Files Size Format View
15010193.pdf 15918KB PDF download
  文献评价指标  
  下载次数:10次 浏览次数:12次