【 摘 要 】
A laboratory test experiment was conducted to measure the energy performance of two different types of water heaters--electric storage tank and demand (tankless)--in two types of plumbing distribution systems--copper piping in a tree configuration and cross-linked polyethylene (PEX) piping in a parallel configuration. Two water-usage patterns were used in the week-long experiments and in the annual simulations: one representing a high-usage home and the other representing a low-usage home. Results of weekly performance testing and annual simulations of electric water-heating systems are presented.
【 预 览 】
Files | Size | Format | View |
---|---|---|---|
15003590.pdf | 890KB | download |