科技报告详细信息
Performance Comparison of Residential Hot Water Systems; Period of Performance: January 30, 2001 through July 29, 2002
Wiehagen, J. ; Sikora, J. L.
National Renewable Energy Laboratory (U.S.)
关键词: Buildings;    Geothermal Legacy;    32 Energy Conservation, Consumption, And Utilization;    Water Heating Geothermal Legacy;    Water;   
DOI  :  10.2172/15003590
RP-ID  :  NREL/SR-550-32922
RP-ID  :  AC36-99-GO10337
RP-ID  :  15003590
美国|英语
来源: UNT Digital Library
PDF
【 摘 要 】

A laboratory test experiment was conducted to measure the energy performance of two different types of water heaters--electric storage tank and demand (tankless)--in two types of plumbing distribution systems--copper piping in a tree configuration and cross-linked polyethylene (PEX) piping in a parallel configuration. Two water-usage patterns were used in the week-long experiments and in the annual simulations: one representing a high-usage home and the other representing a low-usage home. Results of weekly performance testing and annual simulations of electric water-heating systems are presented.

【 预 览 】
附件列表
Files Size Format View
15003590.pdf 890KB PDF download
  文献评价指标  