科技报告详细信息
Oboe Transparency Results - Oboes 1-9
Heinle, R A
Lawrence Livermore National Laboratory
关键词: Fission;    98 Nuclear Disarmament, Safeguards, And Physical Protection;    Testing;    Nuclear Energy;    Dosemeters;   
DOI  :  10.2172/15002117
RP-ID  :  UCRL-ID-150140
RP-ID  :  W-7405-ENG-48
RP-ID  :  15002117
美国|英语
来源: UNT Digital Library
PDF
【 摘 要 】

The motivation for the ''Transparency'' experiment is that DOE/DP would like to have data available to show to interested parties, such as the JASONs. The U1a subcritical experiments are consistent with U.S. policy on nuclear testing. This would be done in a spirit of ''Transparency'' if doubts should arise. Thus, the objective of the ''Transparency'' measurements on the Oboe series is to place an upper bound on the nuclear energy released in the subcritical experiments. Two separate experimental packages cover the transparency measurement issue thoroughly. These are: (1) Neutron Track-Etch Dosimetry. (2) Scintillator Fission Neutron/Gamma Rate Measurement. Because the containment barrier is only 1-inch steel, plus 6-inch shotcrete, it is quite transparent to fission neutrons and, thus, both experiments can be mounted outside the containment barrier and can be recovered post shot. An additional group of dosimeters was placed on the lid of the vessel for greater sensitivity.

【 预 览 】
附件列表
Files Size Format View
15002117.pdf 3192KB PDF download
  文献评价指标  
  下载次数:15次 浏览次数:25次