科技报告详细信息
Cladding Attachment Over Thick Exterior Insulating Sheathing (Fact Sheet)
National Renewable Energy Laboratory (U.S.)
关键词: Furring Strips;    Residential Buildings;    Cladding Attachment;    Exterior Insulation;    Thermal Resistance;   
DOI  :  10.2172/1114058
RP-ID  :  DOE/GO-102013-4057
RP-ID  :  AC36-08GO28308
RP-ID  :  1114058
美国|英语
来源: UNT Digital Library
PDF
【 摘 要 】

The addition of insulation to the exterior of buildings is an effective means of increasing the thermal resistance of wood-framed walls and mass masonry wall assemblies. The location of the insulation on the exterior of the structure has many direct benefits, including better effective R-value from reduced thermal bridging, better condensation resistance, reduced thermal stress on the structure, as well as other commonly associated improvements such as increased airtightness and improved water management. For thick layers of exterior insulation (more than 1.5 in.), the use of wood furring strips attached through the insulation back to the structure has been used by many contractors and designers as a means to provide a convenient cladding attachment location. Although the approach has proven effective, there is significant resistance to its widespread implementation due to a lack of research and understanding of the mechanisms involved in the development of the vertical displacement resistance capacity. In addition, the long-term in-service performance of the system has been questioned due to potential creep effects of the assembly under the sustained dead load of the cladding and effects of varying environmental conditions. In addition, the current International Building Code (IBC) and International Residential Code (IRC) do not have a provision that specifically allows this assembly.

【 预 览 】
附件列表
Files Size Format View
1114058.pdf 616KB PDF download
  文献评价指标  
  下载次数:10次 浏览次数:8次