Predicting Envelope Leakage in Attached Dwellings
Faakye, O. ; Arena, L. ; Griffiths, D.
National Renewable Energy Laboratory (U.S.)
关键词: Multi-Family;    Infiltration Rates;    Attached Dwelling;    Building Tightness;    Buildings;   
DOI  :  10.2172/1089601
RP-ID  :  DOE/GO-102013-3939
RP-ID  :  AC36-08GO28308
RP-ID  :  1089601
美国|英语
来源: UNT Digital Library
PDF
【 摘 要 】

The most common method for measuring air leakage is to use a single blower door to pressurize and/or depressurize the test unit. In detached housing, the test unit is the entire home and the single blower door measures air leakage to the outside. In attached housing, this 'single unit', 'total', or 'solo' test method measures both the air leakage between adjacent units through common surfaces as well air leakage to the outside. Measuring and minimizing this total leakage is recommended to avoid indoor air quality issues between units, reduce energy losses to the outside, reduce pressure differentials between units, and control stack effect. However, two significant limitations of the total leakage measurement in attached housing are: for retrofit work, if total leakage is assumed to be all to the outside, the energy benefits of air sealing can be significantly over predicted; for new construction, the total leakage values may result in failing to meet an energy-based house tightness program criterion. The scope of this research is to investigate an approach for developing a viable simplified algorithm that can be used by contractors to assess energy efficiency program qualification and/or compliance based upon solo test results.

【 预 览 】
附件列表
Files Size Format View
1089601.pdf 1234KB PDF download
  文献评价指标  
  下载次数:13次 浏览次数:36次