科技报告详细信息
| Duration Test Report for the Viryd CS8 Wind Turbine | |
| Roadman, J. ; Murphy, M. ; van Dam, J. | |
| National Renewable Energy Laboratory (U.S.) | |
| 关键词: 17 Wind Energy Viryd Cs8 Wind Turbine; Duration Test; Nrel; Viryd Cs8 Wind Turbine; Wind Energy; | |
| DOI : 10.2172/1087252 RP-ID : NREL/TP-5000-58970 RP-ID : AC36-08GO28308 RP-ID : 1087252 |
|
| 美国|英语 | |
| 来源: UNT Digital Library | |
PDF
|
|
【 摘 要 】
This report summarizes the results of a duration noise test that the National Renewable Energy Laboratory (NREL) conducted on the Viryd CS8 wind turbine. This test was conducted in accordance with Clause 9.4 of the International Electrotechnical Commission's (IEC) standard, Wind turbines - Part 2: Design requirements for small wind turbines, IEC 61400-2 Ed. 2.0:2006-03. NREL researchers evaluated the turbine based on structural integrity and material degradation, quality of environmental protection, and dynamic behavior.
【 预 览 】
| Files | Size | Format | View |
|---|---|---|---|
| 1087252.pdf | 5659KB |
PDF