科技报告详细信息
Laboratory Evaluation of Gas-Fired Tankless and Storage Water Heater Approaches to Combination Water and Space Heating
Kingston, T. ; Scott, S.
National Renewable Energy Laboratory (U.S.)
关键词: Buildings;    32 Energy Conservation, Consumption, And Utilization Combined Space And Water Heating Systems;    Combo Systems;    Laboratory Tests;    Residential;   
DOI  :  10.2172/1069154
RP-ID  :  DOE/GO-102013-3830
RP-ID  :  AC36-08GO28308
RP-ID  :  1069154
美国|英语
来源: UNT Digital Library
PDF
【 摘 要 】
Homebuilders are exploring more cost effective combined space and water heating systems (combo systems) with major water heater manufacturers that are offering pre-engineered forced air space heating combo systems. In this project, unlike standardized tests, laboratory tests were conducted that subjected condensing tankless and storage water heater based combo systems to realistic, coincidental space and domestic hot water loads with the following key findings: 1) The tankless combo system maintained more stable DHW and space heating temperatures than the storage combo system. 2) The tankless combo system consistently achieved better daily efficiencies (i.e. 84%-93%) than the storage combo system (i.e. 81%- 91%) when the air handler was sized adequately and adjusted properly to achieve significant condensing operation. When condensing operation was not achieved, both systems performed with lower (i.e. 75%-88%), but similar efficiencies. 3) Air handlers currently packaged with combo systems are not designed to optimize condensing operation. More research is needed to develop air handlers specifically designed for condensing water heaters. 4) System efficiencies greater than 90% were achieved only on days where continual and steady space heating loads were required with significant condensing operation. For days where heating was more intermittent, the system efficiencies fell below 90%.
【 预 览 】
附件列表
Files Size Format View
1069154.pdf 11040KB PDF download
  文献评价指标  
  下载次数:2次 浏览次数:6次