科技报告详细信息
Evaluation of the Effective Moisture Penetration Depth Model for Estimating Moisture Buffering in Buildings
Woods, J. ; Winkler, J. ; Christensen, D.
National Renewable Energy Laboratory (U.S.)
关键词: Buildings;    National Renewable Energy Laboratory;    Effective Capacitance (Ec) Model;    Building Simulation Test Cases;    Electricity, Resources, And Buildings Systems;   
DOI  :  10.2172/1067948
RP-ID  :  NREL/TP-5500-57441
RP-ID  :  AC36-08GO28308
RP-ID  :  1067948
美国|英语
来源: UNT Digital Library
PDF
【 摘 要 】

This study examines the effective moisture penetration depth (EMPD) model, and its suitability for building simulations. The EMPD model is a compromise between the simple, inaccurate effective capacitance approach and the complex, yet accurate, finite-difference approach. Two formulations of the EMPD model were examined, including the model used in the EnergyPlus building simulation software. An error in the EMPD model we uncovered was fixed with the release of EnergyPlus version 7.2, and the EMPD model in earlier versions of EnergyPlus should not be used.

【 预 览 】
附件列表
Files Size Format View
1067948.pdf 1169KB PDF download
  文献评价指标  