ANALYSIS OF HARRELL MONOSODIUM TITANATE LOT #s 46000606120, 46000722120, AND 46000808120 | |
Taylor-Pashow, K. | |
Savannah River Site (S.C.) | |
关键词: 37 Inorganic, Organic, Physical, And Analytical Chemistry; | |
DOI : 10.2172/1053234 RP-ID : SRNL-STI-2012-00629 RP-ID : DE-AC09-08SR22470 RP-ID : 1053234 |
|
美国|英语 | |
来源: UNT Digital Library | |
【 摘 要 】
Monosodium titanate (MST) for use in the Actinide Removal Process (ARP) must be qualified and verified in advance. A single qualification sample for each batch of material is sent to SRNL for analysis, as well as a statistical sampling of verification samples. The Harrell Industries Lot #s 46000706120, 46000722120, and 460008081120 qualification and verification samples met each of the selected specification requirements that were tested with the exception of a few pails being marginally below the lower weight percent solids limit. These deviations from the specifications are viewed as negligible since the corresponding density of the slurries indicates no appreciable shortage of MST solids. Therefore, SRNL recommends acceptance and use of these pails.