科技报告详细信息
EVALUATION OF ALTERNATIVE FILTER MEDIA FOR THE ROTARY MICROFILTER, PHASE 2
Fowley, M.
Savannah River Site (S.C.)
关键词: Sludges;    Membranes;    Filtration;    Recommendations;    Thickness;   
DOI  :  10.2172/1049528
RP-ID  :  SRNL-STI-2012-00523
RP-ID  :  DE-AC09-08SR22470
RP-ID  :  1049528
美国|英语
来源: UNT Digital Library
PDF
【 摘 要 】

Testing was conducted at the Savannah River National Laboratory (SRNL) to investigate filter membrane performance in an effort to increase rotary microfilter (RMF) throughput. Membranes were tested in the SpinTek Filtration, Inc. Static Test Cell (STC), which permitted quick and easy testing of several different membranes. Testing consisted of 100 hours tests with two different slurry feeds, based on recommendations from the phase 1 testing. One feed contained Monosodium Titanate (MST) solids in a simulated salt solution. The other feed contained simulated sludge batch 6 (SB6) solids in a simulated salt solution. Five membranes were tested, one each from filter manufactures Pall and Porvair and three from the Oak Ridge National Laboratory (ORNL). The membrane from Pall is the current membrane used on the latest generation RMF. The Porvair membrane performed well in previous STC tests as well as one of the ORNL membranes. The other two membranes from ORNL were recently developed and not available for the previous STC test. The results indicate that the Porvair filter performed best with the MST slurry and the ORNL SVB6-1B filter performed best with the SB6 slurry. Difficulty was encountered with the ORNL filters due to their dimensional thickness, which was greater than the recommended filter thickness for the STC. The STC equipment was modified to complete the testing of the ORNL filters.

【 预 览 】
附件列表
Files Size Format View
1049528.pdf 14413KB PDF download
  文献评价指标  
  下载次数:27次 浏览次数:15次