科技报告详细信息
Summary of TRUEX Radiolysis Testing Using the INL Radiolysis Test Loop
Peterman, Dean R. ; Olson, Lonnie G. ; McDowell, Rocklan G. ; Elias, Gracy ; Law, Jack D.
Idaho National Laboratory
关键词: Flowsheets;    Radiolysis;    Europium;    Irradiation;    Actinides;   
DOI  :  10.2172/1046071
RP-ID  :  INL/EXT-12-25311
RP-ID  :  DE-AC07-05ID14517
RP-ID  :  1046071
美国|英语
来源: UNT Digital Library
PDF
【 摘 要 】

The INL radiolysis and hydrolysis test loop has been used to evaluate the effects of hydrolytic and radiolytic degradation upon the efficacy of the TRUEX flowsheet for the recovery of trivalent actinides and lanthanides from acidic solution. Repeated irradiation and subsequent re-conditioning cycles did result in a significant decrease in the concentration of the TBP and CMPO extractants in the TRUEX solvent and a corresponding decrease in americium and europium extraction distributions. However, the build-up of solvent degradation products upon {gamma}-irradiation, had little impact upon the efficiency of the stripping section of the TRUEX flowsheet. Operation of the TRUEX flowsheet would require careful monitoring to ensure extraction distributions are maintained at acceptable levels.

【 预 览 】
附件列表
Files Size Format View
1046071.pdf 444KB PDF download
  文献评价指标  
  下载次数:15次 浏览次数:16次