| MicroCT: Automated Analysis of CT Reconstructed Data of Home Made Explosive Materials Using the Matlab MicroCT Analysis GUI | |
| Seetho, I M ; Brown, W D ; Kallman, J S ; Martz, H E ; White, W T | |
| Lawrence Livermore National Laboratory | |
| 关键词: Lawrence Livermore National Laboratory; Data Acquisition; 42 Engineering; Production; Quality Assurance; | |
| DOI : 10.2172/1037841 RP-ID : LLNL-TR-503291 RP-ID : W-7405-ENG-48 RP-ID : 1037841 |
|
| 美国|英语 | |
| 来源: UNT Digital Library | |
PDF
|
|
【 摘 要 】
This Standard Operating Procedure (SOP) provides the specific procedural steps for analyzing reconstructed CT images obtained under the IDD Standard Operating Procedures for data acquisition [1] and MicroCT image reconstruction [2], per the IDD Quality Assurance Plan for MicroCT Scanning [3]. Although intended to apply primarily to MicroCT data acquired in the HEAFCAT Facility at LLNL, these procedures may also be applied to data acquired at Tyndall from the YXLON cabinet and at TSL from the HEXCAT system. This SOP also provides the procedural steps for preparing the tables and graphs to be used in the reporting of analytical results. This SOP applies to production work - for R and D there are two other semi-automated methods as given in [4, 5].