科技报告详细信息
Signal conditioning circuitry design for instrumentation systems.
Larsen, Cory A.
Sandia National Laboratories
关键词: Transducers;    Amplitudes;    Implementation;    Analog-To-Digital Converters;    Sensors;   
DOI  :  10.2172/1034887
RP-ID  :  SAND2011-9467
RP-ID  :  AC04-94AL85000
RP-ID  :  1034887
美国|英语
来源: UNT Digital Library
PDF
【 摘 要 】

This report details the current progress in the design, implementation, and validation of the signal conditioning circuitry used in a measurement instrumentation system. The purpose of this text is to document the current progress of a particular design in signal conditioning circuitry in an instrumentation system. The input of the signal conditioning circuitry comes from a piezoresistive transducer and the output will be fed to a 250 ksps, 12-bit analog-to-digital converter (ADC) with an input range of 0-5 V. It is assumed that the maximum differential voltage amplitude input from the sensor is 20 mV with an unknown, but presumably high, sensor bandwidth. This text focuses on a specific design; however, the theory is presented in such a way that this text can be used as a basis for future designs.

【 预 览 】
附件列表
Files Size Format View
1034887.pdf 668KB PDF download
  文献评价指标  
  下载次数:18次 浏览次数:33次